Category 6 Cable, 4 Pair, U/UTP, PVC Indoor CPR Eca

Category 6 Premise Horizontal Cable (250MHz), 4-Pair, 23 AWG solid bare copper conductors, U/UTP, Polyethylene insulation, PVC jacket, CPR Eca

Specifications


Conductor

Suitable Applications

Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM

ElementSizeStrandingMaterialNo. of PairsNo. of Elements
Individual Pair23 AWGSolidBC - Bare Copper48

Insulation


Cable Core

ElementMaterialNom. Insulation DiameterColor Code
Individual PairPE - Polyethylene0.96 mm (0.038 in)White/Blue & Blue, White/Green & Green, White/Orange & Orange, White/Brown & Brown
DescriptionSeparator
4 pairs twisted togetherCenter Member (Patented X-Spline®)

Outer Jacket

MaterialNom. Diameter
PVC - Polyvinyl Chloride5.4 mm (0.21 in)


Overall Cable Diameter (Nominal)

5.4 mm (0.21 in)


Electricals

Max. Conductor DCRMax. Mutual CapacitanceMax. Capacitance UnbalanceNom. Characteristic Impedance
95 Ohm/km (29 Ohm/1000ft)56 pF/m (17 pF/ft)160 pF/100m100 Ohm

Delay

Max. Delay SkewNom. Velocity of Prop.
40 ns/100m70>#/td###

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.1 dB/100m75.372.373.270.27067204035
43.8 dB/100m66.363.362.459.45855233423
106 dB/100m60.357.354.351.35047253015
167.6 dB/100m57.254.249.646.645.942.9252810.9
208.5 dB/100m55.852.847.344.3444125279
31.210.7 dB/100m52.949.942.139.140.137.123.625.15.1
62.515.5 dB/100m48.445.432.929.934.131.121.522
10019.9 dB/100m45.342.325.422.4302720.120
15525.3 dB/100m42.439.417.114.126.223.218.818.1
20029.1 dB/100m40.837.811.68.624211817
25033 dB/100m39.336.36.33.3221917.316

Table Notes

Limits below 4 MHz are for information only. Reference standard: IEC 61156-5

Screening Class

Type III

Table Notes

Coupling Attenuation

Voltage


Voltage Rating
72 V DC